Aantar Books
Weighing Scale Setup
Connect a USB, serial or network weighing scale to this computer, so an item sold by weight takes its quantity from the scale.
Where: File ▸ Weighing Scale Setup…
Weighing Scale Setup connects a weighing scale to this computer. Once a scale is connected, an item marked to be sold by weight takes its quantity from the scale automatically when it is added to a sale.
The menu item is shown only when weighing is switched on for your business. The scale belongs to this computer: each computer connects its own.
Opening it
File ▸ Weighing Scale Setup… opens it in a window of its own. Esc closes it.
Connect a scale
- Plug the scale in and switch it on.
- Look under Detected scales. A USB scale appears on its own as USB scale; a serial scale shows as the COM port its cable is on, with its speed (for example Serial COM3 · 9600 baud, 8-N-1).
- Click Connect beside it. The top of the page then shows the scale's name.
- Put something on the platter. The weight should change on the page (… on the scale). If it does not move, or the number looks wrong, the scale is not talking to this computer the way it should: check the cable and its settings.
If nothing is found, the page says No scale found. Switch the scale on and click Scan again.
A scale that has gone to sleep shows Scale asleep — waiting for it: press its power button and it is picked up again. Disconnect releases it.
A network scale
Some scales sit on the network behind a small serial-to-network box.
- Click Add network scale.
- Type the box's IP address or host (for example 192.168.1.50) and its Port — usually 4001 (Moxa), 10001 (Lantronix) or 8000.
- Click Test, then Use this scale.
Only one computer reads a network scale at a time. If another has it, the page names that computer; adding it here moves it to this one.
Units
Under Units, choose the unit weighed items are priced in. The scale's reading is converted to it automatically.
Items sold by weight
An item takes its quantity from the scale when it is set to be sold by weight on its form. See Add or edit an item.
Common problems
The weight does not change. The scale is connected but not sending readings this computer understands. Check that the cable is the right one and, for a serial scale, that its speed matches.
The scale is not listed. Switch it on and click Scan again. A serial scale must be on a COM port; a network scale is added with Add network scale.
Something unclear or out of date? Write to support@aantar.com and name this page.